News

What safety issues should be paid attention to during the operation of the closed cooling tower?

Publish Time: 2024-11-25
As an important part of the industrial cooling system, the closed cooling tower needs to pay attention to multiple safety issues during operation to ensure the stable operation of the equipment and the safety of personnel.

First of all, the closed cooling tower needs to be maintained and inspected regularly during operation. This includes checking whether the key components of the equipment, such as the electrical system, control system, spray system, heat exchanger, etc., are working properly. At the same time, it is necessary to check whether the fasteners of the equipment are loose to avoid equipment vibration and noise caused by looseness, as well as possible equipment failures and safety accidents.

Secondly, the closed cooling tower needs to pay attention to water quality safety during operation. Since the closed cooling tower uses circulating water for cooling, the quality of water directly affects the cooling effect and life of the equipment. During operation, the water quality needs to be tested regularly to ensure that the impurities, microorganisms and corrosive substances in the water are controlled within a reasonable range. At the same time, the cooling water needs to be cleaned and replaced regularly to avoid damage to the equipment caused by water quality deterioration.

In addition, the closed cooling tower also needs to pay attention to anti-freeze measures during operation. In cold seasons, if the circulating water inside the equipment freezes, it will cause equipment damage and safety accidents. Therefore, when operating a closed cooling tower in winter, appropriate antifreeze measures need to be taken, such as adding antifreeze and maintaining the internal temperature of the equipment.

Finally, the closed cooling tower also needs to pay attention to the safety of the electrical system during operation. The electrical system of the equipment includes components such as motors, cables, switches, etc. If the electrical system fails or short-circuits, it will cause safety accidents such as fire and electric shock. Therefore, during operation, it is necessary to regularly check the insulation performance and grounding of the electrical system to ensure the safety and reliability of the electrical system.

In summary, during operation, the closed cooling tower needs to pay attention to maintenance and inspection, water quality safety, antifreeze measures, and electrical system safety. Only by ensuring that these safety issues are effectively resolved can the stable operation of the closed cooling tower and the safety of personnel be guaranteed. Therefore, relevant operators need to have certain professional knowledge and operating skills, and strictly follow the operating procedures to operate and maintain the equipment.
×

Contact Us

captcha